open access

Vol 68, No 9 (2010)
Invasive electrophysiology
Published online: 2010-09-21
Submitted: 2012-12-28
Get Citation

Inappropriate sinus tachycardia - non-contact mapping and ablation

Marek Jastrzębski, Bogumiła Bacior, Agnieszka Olszanecka, Kalina-Kawecka Jaszcz
Kardiol Pol 2010;68(9):1079-1082.

open access

Vol 68, No 9 (2010)
Invasive electrophysiology
Published online: 2010-09-21
Submitted: 2012-12-28

Abstract

Two cases of inappropriate sinus tachycardia refractory to combined pharmacotherapy (beta-blocker, ivabradine) are described. Both were female patients (28 and 45 years-old) and underwent sinus node modification/ablation using non-contact mapping (EnSite Array). Since ablation had to be performed in both cases very close to the phrenic nerve (captured during 10V pacing at ablation spots) its function was monitored during ablation with constant phrenic nerve pacing from the superior vena cava. One case was successful after single and straightforward ablation session, the other case despite several attempts and initially good result had recurrences; first recurrence two days after cryoablation, and second three weeks after radiofrequency ablation with irrigated tip catheter.
Kardiol Pol 2010; 68, 9: 1079-1082

Abstract

Two cases of inappropriate sinus tachycardia refractory to combined pharmacotherapy (beta-blocker, ivabradine) are described. Both were female patients (28 and 45 years-old) and underwent sinus node modification/ablation using non-contact mapping (EnSite Array). Since ablation had to be performed in both cases very close to the phrenic nerve (captured during 10V pacing at ablation spots) its function was monitored during ablation with constant phrenic nerve pacing from the superior vena cava. One case was successful after single and straightforward ablation session, the other case despite several attempts and initially good result had recurrences; first recurrence two days after cryoablation, and second three weeks after radiofrequency ablation with irrigated tip catheter.
Kardiol Pol 2010; 68, 9: 1079-1082
Get Citation

Keywords

inappropriate sinus tachycardia; ablation; cryoablation; non-contact mapping

About this article
Title

Inappropriate sinus tachycardia - non-contact mapping and ablation

Journal

Kardiologia Polska (Polish Heart Journal)

Issue

Vol 68, No 9 (2010)

Pages

1079-1082

Published online

2010-09-21

Bibliographic record

Kardiol Pol 2010;68(9):1079-1082.

Keywords

inappropriate sinus tachycardia
ablation
cryoablation
non-contact mapping

Authors

Marek Jastrzębski
Bogumiła Bacior
Agnieszka Olszanecka
Kalina-Kawecka Jaszcz

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.