Transcatheter implantation of Edwards-SAPIEN THV valve in pulmonary position

Roland Fiszer, Małgorzata Szkutnik, Ziyad M. Hijazi, Jacek Białkowski
Kardiol Pol 2011;69(7):749-750.

open access

Vol 69, No 7 (2011)
Nasze forum - kardiolodzy i kardiochirurdzy razem
Published online: 2011-07-18
Submitted: 2012-12-28

Abstract

Transcatheter pulmonary valve implantation improves conduit haemodynamics without necessity of complex reoperation. Clinical experience with application of the Edwards-SAPIEN Transcatheter Heart Valve (THV) in pulmonary position is still limited. We present data of 2 patients (21 year-old woman and 26 year-old man) with a history of dysfunction of homograft in position of right ventricular outflow tract (RVOT), in whom the Edwards-SAPIEN THV was successfuly implanted.
Kardiol Pol 2011; 69, 7: 749–750

Abstract

Transcatheter pulmonary valve implantation improves conduit haemodynamics without necessity of complex reoperation. Clinical experience with application of the Edwards-SAPIEN Transcatheter Heart Valve (THV) in pulmonary position is still limited. We present data of 2 patients (21 year-old woman and 26 year-old man) with a history of dysfunction of homograft in position of right ventricular outflow tract (RVOT), in whom the Edwards-SAPIEN THV was successfuly implanted.
Kardiol Pol 2011; 69, 7: 749–750
Get Citation

Keywords

interventional cardiology; pulmonary homograft; Edwards-SAPIEN THV

About this article
Title

Transcatheter implantation of Edwards-SAPIEN THV valve in pulmonary position

Journal

Kardiologia Polska (Polish Heart Journal)

Issue

Vol 69, No 7 (2011)

Pages

749-750

Published online

2011-07-18

Bibliographic record

Kardiol Pol 2011;69(7):749-750.

Keywords

interventional cardiology
pulmonary homograft
Edwards-SAPIEN THV

Authors

Roland Fiszer
Małgorzata Szkutnik
Ziyad M. Hijazi
Jacek Białkowski

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By "Via Medica sp. z o.o." sp.k., Świętokrzyska 73 street, 80–180 Gdańsk, Poland

tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail: viamedica@viamedica.pl