open access

Vol 64, No 5 (2006)
Other
Published online: 2006-06-01
Submitted: 2012-12-28
Get Citation

Original article
Transcoronary stem cell delivery using physiological endothelium-targeting perfusion technique: the rationale and a pilot study involving a comparison with conventional over-the-wire balloon coronary occlusions in patients after recent myocardial infarction

Tomasz Siminiak
Kardiol Pol 2006;64(5):489-498.

open access

Vol 64, No 5 (2006)
Other
Published online: 2006-06-01
Submitted: 2012-12-28

Abstract

Introduction: Recent evidence shows poor efficacy of over-the-wire balloon catheter (OTW) coronary occlusive technique adopted widely for intracoronary bone marrow stem cell (BMSC) delivery. The waterfall effect of OTW-balloon inflation/deflation with reactive ł2-fold flow velocity increase might be partly responsible for poor BMSC retention. Aim: To evaluate the safety, feasibility and tolerability of perfusion-infusion BMSC delivery with the facilitation of cell rolling in contact with the coronary endothelium (a pre-requisite for downstream transmigration). Methods: We randomly assigned 11 patients (age 41-72 years) with first anterior myocardial infarction treated with PTCA+stent and LVEF ≤45% at 6-9 days to OTW in-stent occlusive (3 x 3 min.) BMSC delivery or cell infusion via a perfusion catheter with multiple side holes (SH-PC). Results: OTW and SH-PC patients had a similar infarct size (mean peak CK 4361 vs 4717 U/L), LVEF (41.2% vs 40.3%), infused mononuclear cell number (2.99 x 108 range 0.61-7.48 x 108 vs 3.28 x 108 range 1.64-4.39 x 108), CD 34+ number (1.79 x 106 vs 1.62 x 106), cell viability (91.5% vs 91.8%) and clonogenicity (CFU assay). None of the SH-PC, but 67% of OTW patients, had ST-segment elevation with chest pain (and nsVT in one) that limited OTW occlusion tolerance to 50-110 sec. At 6 months DLVEF in the OTW vs SH-PC patients was +4.2% (2-6) vs +8.8% (5-16) by MRI and +4.8 (2-7) vs +13.8% (2-24) by SPECT. Conclusions: Our work indicates that the SH-PC technique can be used safely for intracoronary BMSC transplantation. Further research is needed to determine whether the putative advantages of physiological SH-PC delivery translate into enhanced BMSC homing.

Abstract

Introduction: Recent evidence shows poor efficacy of over-the-wire balloon catheter (OTW) coronary occlusive technique adopted widely for intracoronary bone marrow stem cell (BMSC) delivery. The waterfall effect of OTW-balloon inflation/deflation with reactive ł2-fold flow velocity increase might be partly responsible for poor BMSC retention. Aim: To evaluate the safety, feasibility and tolerability of perfusion-infusion BMSC delivery with the facilitation of cell rolling in contact with the coronary endothelium (a pre-requisite for downstream transmigration). Methods: We randomly assigned 11 patients (age 41-72 years) with first anterior myocardial infarction treated with PTCA+stent and LVEF ≤45% at 6-9 days to OTW in-stent occlusive (3 x 3 min.) BMSC delivery or cell infusion via a perfusion catheter with multiple side holes (SH-PC). Results: OTW and SH-PC patients had a similar infarct size (mean peak CK 4361 vs 4717 U/L), LVEF (41.2% vs 40.3%), infused mononuclear cell number (2.99 x 108 range 0.61-7.48 x 108 vs 3.28 x 108 range 1.64-4.39 x 108), CD 34+ number (1.79 x 106 vs 1.62 x 106), cell viability (91.5% vs 91.8%) and clonogenicity (CFU assay). None of the SH-PC, but 67% of OTW patients, had ST-segment elevation with chest pain (and nsVT in one) that limited OTW occlusion tolerance to 50-110 sec. At 6 months DLVEF in the OTW vs SH-PC patients was +4.2% (2-6) vs +8.8% (5-16) by MRI and +4.8 (2-7) vs +13.8% (2-24) by SPECT. Conclusions: Our work indicates that the SH-PC technique can be used safely for intracoronary BMSC transplantation. Further research is needed to determine whether the putative advantages of physiological SH-PC delivery translate into enhanced BMSC homing.
Get Citation

Keywords

stem cell therapy; transcoronary bone marrow stem cell transplantation; physiological stem cell delivery; endothelium-targeted stem cell delivery; myocardial infarction border zone regeneration

About this article
Title

Original article
Transcoronary stem cell delivery using physiological endothelium-targeting perfusion technique: the rationale and a pilot study involving a comparison with conventional over-the-wire balloon coronary occlusions in patients after recent myocardial infarction

Journal

Kardiologia Polska (Polish Heart Journal)

Issue

Vol 64, No 5 (2006)

Pages

489-498

Published online

2006-06-01

Bibliographic record

Kardiol Pol 2006;64(5):489-498.

Keywords

stem cell therapy
transcoronary bone marrow stem cell transplantation
physiological stem cell delivery
endothelium-targeted stem cell delivery
myocardial infarction border zone regeneration

Authors

Tomasz Siminiak

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By "Via Medica sp. z o.o." sp.k., Świętokrzyska 73 street, 80–180 Gdańsk, Poland