open access

Vol 65, No 6 (2007)
Other
Published online: 2007-07-02
Submitted: 2012-12-28
Get Citation

Original article
Prospective randomised study to evaluate effectiveness of distal embolic protection compared to abciximab administration in reduction of microembolic complications of primary coronary angioplasty

Andrzej Ochała, Grzegorz Smolka, Wojciech Wojakowski, Bogna Gabrylewicz, Piotr Garbocz, Michał Tendera
Kardiol Pol 2007;65(6):672-680.

open access

Vol 65, No 6 (2007)
Other
Published online: 2007-07-02
Submitted: 2012-12-28

Abstract

Background: Myocardial reperfusion following primary percutaneous coronary intervention (pPCI) is limited due to, among other things, microembolic events. Abciximab and a mechanical system of distal protection both reduce their incidence during PCI. Aim: Prospective, randomised study to compare effectiveness of abciximab and protection devices in reduction of microembolic complications during pPCI. Methods: One hundred and twenty consecutive patients with ST elevation acute myocardial infarction referred for pPCI after coronary angiography were randomly assigned to the following groups: Group A (n=63), treated with abciximab; and Group B (n=57), treated using the distal protection system. Primary endpoint was blood flow through the infarct-related artery (IRA) using TIMI grading after pPCI; secondary endpoints included myocardial perfusion assessment using myocardial blush grade (MBG), ST resolution and improvement of echocardiographic left ventricular ejection fraction (LVEF) after pPCI. Results: TIMI grade 3 flow after pPCI was obtained in 89% of patients in both groups, TIMI grade 2 flow in 5% (NS). Myocardial perfusion after pPCI assessed with MBG scored 3 in 66% of patients in group A and 62% of patients in group B (NS). ST resolution was present in 62% (26-84) in group A and 68% (41 &#8211; 86) in group B (NS). Logistic regression analysis showed no significant influence of selected variables on the primary endpoint. Analysis performed in the distal protection group revealed significant effects on the following factors on the final TIMI flow in IRA: presence of thrombus prior to pPCI (p=0.026), presence of residual thrombus after aspiration (p <0.001), and IRA diameter of ł3.5 mm (p=0.01). Median LVEF in group A at sixth month of follow-up was 46% (44-50%), similar to group B &#8211; 46% (45-49%) (NS). Conclusions: Use of the PercuSurge distal protection device during pPCI allows angiographic and electrocardiographic measures of reperfusion to be improved. It has a similar effect on left ventricular systolic function as administration of abciximab. The device seems to be useful in patients with culprit artery diameter of ł3.0 mm, and optimally ł3.5 mm and thrombus visible on angiography. Successful initial thrombectomy prior to deployment of stent seems particularly important when using the PercuSurge system.

Abstract

Background: Myocardial reperfusion following primary percutaneous coronary intervention (pPCI) is limited due to, among other things, microembolic events. Abciximab and a mechanical system of distal protection both reduce their incidence during PCI. Aim: Prospective, randomised study to compare effectiveness of abciximab and protection devices in reduction of microembolic complications during pPCI. Methods: One hundred and twenty consecutive patients with ST elevation acute myocardial infarction referred for pPCI after coronary angiography were randomly assigned to the following groups: Group A (n=63), treated with abciximab; and Group B (n=57), treated using the distal protection system. Primary endpoint was blood flow through the infarct-related artery (IRA) using TIMI grading after pPCI; secondary endpoints included myocardial perfusion assessment using myocardial blush grade (MBG), ST resolution and improvement of echocardiographic left ventricular ejection fraction (LVEF) after pPCI. Results: TIMI grade 3 flow after pPCI was obtained in 89% of patients in both groups, TIMI grade 2 flow in 5% (NS). Myocardial perfusion after pPCI assessed with MBG scored 3 in 66% of patients in group A and 62% of patients in group B (NS). ST resolution was present in 62% (26-84) in group A and 68% (41 &#8211; 86) in group B (NS). Logistic regression analysis showed no significant influence of selected variables on the primary endpoint. Analysis performed in the distal protection group revealed significant effects on the following factors on the final TIMI flow in IRA: presence of thrombus prior to pPCI (p=0.026), presence of residual thrombus after aspiration (p <0.001), and IRA diameter of ł3.5 mm (p=0.01). Median LVEF in group A at sixth month of follow-up was 46% (44-50%), similar to group B &#8211; 46% (45-49%) (NS). Conclusions: Use of the PercuSurge distal protection device during pPCI allows angiographic and electrocardiographic measures of reperfusion to be improved. It has a similar effect on left ventricular systolic function as administration of abciximab. The device seems to be useful in patients with culprit artery diameter of ł3.0 mm, and optimally ł3.5 mm and thrombus visible on angiography. Successful initial thrombectomy prior to deployment of stent seems particularly important when using the PercuSurge system.
Get Citation

Keywords

primary coronary angioplasty; myocardial infarction; distal protection; microembolism

About this article
Title

Original article
Prospective randomised study to evaluate effectiveness of distal embolic protection compared to abciximab administration in reduction of microembolic complications of primary coronary angioplasty

Journal

Kardiologia Polska (Polish Heart Journal)

Issue

Vol 65, No 6 (2007)

Pages

672-680

Published online

2007-07-02

Bibliographic record

Kardiol Pol 2007;65(6):672-680.

Keywords

primary coronary angioplasty
myocardial infarction
distal protection
microembolism

Authors

Andrzej Ochała
Grzegorz Smolka
Wojciech Wojakowski
Bogna Gabrylewicz
Piotr Garbocz
Michał Tendera

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.