Cardiac troponin I after external electrical cardioversion for atrial fibrillation as a marker of myocardial injury – a preliminary report

Wiktor Piechota, Grzegorz Gielerak, Robert Ryczek, Anna Kaźmierczak, Jolanta Bejm, Wiesław Piechota
Kardiol Pol 2007;65(6):664-669.

open access

Vol 65, No 6 (2007)
Other
Published online: 2007-07-02
Submitted: 2012-12-28

Abstract

Background: It is uncertain whether external electrical cardioversion (CV) of atrial fibrillation (AF) can cause myocardial injury identifiable by troponin I (cTnI). Aim: To examine whether external CV of AF can cause cTnI rise as measured with high-sensitivity assay, and to identify factors determining this elevation. Methods: Patients with non-valvular AF selected for CV were included. Exclusion criteria were myocardial ischaemia, elevated D-dimer, heart and renal failure. Patients underwent monophasic or biphasic CV. Troponin I was measured before, and 6 and 12 hours after the procedure with TNI-ADV assay; NT-proBNP was measured before CV. Echocardiography was performed in all patients. Results: Twenty-two patients were examined. Troponin I 6 and 12 hours after CV [0.04 ng/ml (0.00-0.30), 0.04 ng/ml (0.00-0.13)] was significantly higher than before [0.017 pg/ml (0.00-0.08)] (p=0.01, p=0.02). Only in one patient did cTnI exceed the cut-off for myocardial infarction after 6 hours (>0.16 ng/ml) with subsequent normalisation after 12 hours. Left ventricular end-diastolic dimension (LVEDD) was significantly higher and ejection fraction lower in the group with cTnI rise in comparison with the group with no cTnI elevation (54,2±6,3 vs. 47,6±5,7 mm, p=0,02; 56,2±8,9 vs. 63,2±7,1%, p=0,05). LVEDD=53 mm had 75% sensitivity and 72% specificity for predicting cTnI elevation after CV. Age, gender, AF duration, type of CV, energy, left atrial dimension, baseline cTnI and NT-proBNP were not predictive of cTnI increase. Conclusions: Cardioversion can lead to mild but significant cTnI rise as measured with a high-sensitivity assay. The influence of CV on cTnI elevation appears to be more pronounced in patients with relatively large LVEDD.

Abstract

Background: It is uncertain whether external electrical cardioversion (CV) of atrial fibrillation (AF) can cause myocardial injury identifiable by troponin I (cTnI). Aim: To examine whether external CV of AF can cause cTnI rise as measured with high-sensitivity assay, and to identify factors determining this elevation. Methods: Patients with non-valvular AF selected for CV were included. Exclusion criteria were myocardial ischaemia, elevated D-dimer, heart and renal failure. Patients underwent monophasic or biphasic CV. Troponin I was measured before, and 6 and 12 hours after the procedure with TNI-ADV assay; NT-proBNP was measured before CV. Echocardiography was performed in all patients. Results: Twenty-two patients were examined. Troponin I 6 and 12 hours after CV [0.04 ng/ml (0.00-0.30), 0.04 ng/ml (0.00-0.13)] was significantly higher than before [0.017 pg/ml (0.00-0.08)] (p=0.01, p=0.02). Only in one patient did cTnI exceed the cut-off for myocardial infarction after 6 hours (>0.16 ng/ml) with subsequent normalisation after 12 hours. Left ventricular end-diastolic dimension (LVEDD) was significantly higher and ejection fraction lower in the group with cTnI rise in comparison with the group with no cTnI elevation (54,2±6,3 vs. 47,6±5,7 mm, p=0,02; 56,2±8,9 vs. 63,2±7,1%, p=0,05). LVEDD=53 mm had 75% sensitivity and 72% specificity for predicting cTnI elevation after CV. Age, gender, AF duration, type of CV, energy, left atrial dimension, baseline cTnI and NT-proBNP were not predictive of cTnI increase. Conclusions: Cardioversion can lead to mild but significant cTnI rise as measured with a high-sensitivity assay. The influence of CV on cTnI elevation appears to be more pronounced in patients with relatively large LVEDD.
Get Citation

Keywords

cardiac troponin I; cardioversion; atrial fibrillation

About this article
Title

Original article
Cardiac troponin I after external electrical cardioversion for atrial fibrillation as a marker of myocardial injury – a preliminary report

Journal

Kardiologia Polska (Polish Heart Journal)

Issue

Vol 65, No 6 (2007)

Pages

664-669

Published online

2007-07-02

Bibliographic record

Kardiol Pol 2007;65(6):664-669.

Keywords

cardiac troponin I
cardioversion
atrial fibrillation

Authors

Wiktor Piechota
Grzegorz Gielerak
Robert Ryczek
Anna Kaźmierczak
Jolanta Bejm
Wiesław Piechota

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By "Via Medica sp. z o.o." sp.k., Świętokrzyska 73 street, 80–180 Gdańsk, Poland

tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail: viamedica@viamedica.pl