Usefulness of electrocardiographic and echocardiographic parameters for predicting the efficacy of atrioventricular synchronisation during a single lead VDD/R pacing

Agnieszka Czunko, Jacek Lelakowski, Jacek Szczepkowski
Kardiol Pol 2009;67(8):1019-1028.

open access

Vol 67, No 8 (2009)
Other
Published online: 2009-09-09
Submitted: 2012-12-28

Abstract

Background: The VDD/R pacing is accepted as an alternative to DDD/R pacing in patients with atrioventricular conduction block (AVB) and intact sinus node function.
Aim: To determine the relationship between parameters obtained during assessment of the patient for the implantation procedure, using electrocardiographic (ECG) and echocardiographic (ECHO) data, and the effectiveness of AV synchronisation.
Methods: The study involved a group of 65 patients (43 males, 22 females), aged 66.6 ± 12.7 with clinically significant disturbances of AV conduction, who did not reveal symptoms of concomitant abnormalities in sinus node automaticity. Selected ECG and ECHO parameters were studied prior to the implantation procedure. Repeat examinations were done at 3-4 days and at 1, 3, 6 and 12 months after the procedure. The effectiveness of AV synchronisation (PAS) has been estimated by event counter read-out and ECG Holter monitoring.
Results: In 74% patients (subgroup A) synchronisation was highly effective (PAS ł 95%); in the remaining 26% subjects (subgroup B) PAS occasionally fell below 95%. In subgroup B, the P wave was longer than that in subgroup A (105 ± 16 vs. 92 ± 13 ms; p < 0.05). The dimensions of the right and left heart chambers were greater in subgroup B. Patients in subgroup B had lower ejection fraction (49.4 ± 13.7% in B vs. 58.2 ± 11.3% in A) and revealed symptoms of heart failure. The following cut-off values for each echocardiographic and electrocardiographic parameter predisposing to PAS < 95% during VDD/R pacing (‘undersensing’) were identified: RVEDd > 26 mm, RVESd > 24 mm, LVEDd > 59 mm, LVESd > 37.3 mm, APD LA > 44 mm, SID RA > 52 mm, LMD RA > 48 mm, RAvol > 54 ml, RAarea > 19 cm2, SID LA > 57 mm, LMD LA > 46 mm, EF < 52%, P wave width > 100 ms. Significant predictors of PAS < 95% in the univariate analysis were RVEDd, RVESd, LVEDd, LMD RA, SID RA, RAvol, RAarea, EF, and in the multivariate analysis RVEDd, RVESd, LMD RA, RAarea, EF.
Conclusions: Selected parameters obtained from ECG (P wave width) and echo examinations are correlated with effective AV synchronisation. Enlargement of the right and left heart chambers (atrial, ventricular), reduction of the ejection fraction and congestive heart failure are associated with impaired AV synchronisation in VDD/R pacemakers. In multivariate analysis, only the higher dimensions of the right ventricle and atrium and the lower ejection fraction of the left ventricle were significantly associated with the PAS < 95%.

Abstract

Background: The VDD/R pacing is accepted as an alternative to DDD/R pacing in patients with atrioventricular conduction block (AVB) and intact sinus node function.
Aim: To determine the relationship between parameters obtained during assessment of the patient for the implantation procedure, using electrocardiographic (ECG) and echocardiographic (ECHO) data, and the effectiveness of AV synchronisation.
Methods: The study involved a group of 65 patients (43 males, 22 females), aged 66.6 ± 12.7 with clinically significant disturbances of AV conduction, who did not reveal symptoms of concomitant abnormalities in sinus node automaticity. Selected ECG and ECHO parameters were studied prior to the implantation procedure. Repeat examinations were done at 3-4 days and at 1, 3, 6 and 12 months after the procedure. The effectiveness of AV synchronisation (PAS) has been estimated by event counter read-out and ECG Holter monitoring.
Results: In 74% patients (subgroup A) synchronisation was highly effective (PAS ł 95%); in the remaining 26% subjects (subgroup B) PAS occasionally fell below 95%. In subgroup B, the P wave was longer than that in subgroup A (105 ± 16 vs. 92 ± 13 ms; p < 0.05). The dimensions of the right and left heart chambers were greater in subgroup B. Patients in subgroup B had lower ejection fraction (49.4 ± 13.7% in B vs. 58.2 ± 11.3% in A) and revealed symptoms of heart failure. The following cut-off values for each echocardiographic and electrocardiographic parameter predisposing to PAS < 95% during VDD/R pacing (‘undersensing’) were identified: RVEDd > 26 mm, RVESd > 24 mm, LVEDd > 59 mm, LVESd > 37.3 mm, APD LA > 44 mm, SID RA > 52 mm, LMD RA > 48 mm, RAvol > 54 ml, RAarea > 19 cm2, SID LA > 57 mm, LMD LA > 46 mm, EF < 52%, P wave width > 100 ms. Significant predictors of PAS < 95% in the univariate analysis were RVEDd, RVESd, LVEDd, LMD RA, SID RA, RAvol, RAarea, EF, and in the multivariate analysis RVEDd, RVESd, LMD RA, RAarea, EF.
Conclusions: Selected parameters obtained from ECG (P wave width) and echo examinations are correlated with effective AV synchronisation. Enlargement of the right and left heart chambers (atrial, ventricular), reduction of the ejection fraction and congestive heart failure are associated with impaired AV synchronisation in VDD/R pacemakers. In multivariate analysis, only the higher dimensions of the right ventricle and atrium and the lower ejection fraction of the left ventricle were significantly associated with the PAS < 95%.
Get Citation

Keywords

VDD stimulation; AV synchronisation; ECG and ECHO parameters

About this article
Title

Original article
Usefulness of electrocardiographic and echocardiographic parameters for predicting the efficacy of atrioventricular synchronisation during a single lead VDD/R pacing

Journal

Kardiologia Polska (Polish Heart Journal)

Issue

Vol 67, No 8 (2009)

Pages

1019-1028

Published online

2009-09-09

Bibliographic record

Kardiol Pol 2009;67(8):1019-1028.

Keywords

VDD stimulation
AV synchronisation
ECG and ECHO parameters

Authors

Agnieszka Czunko
Jacek Lelakowski
Jacek Szczepkowski

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By "Via Medica sp. z o.o." sp.k., Świętokrzyska 73 street, 80–180 Gdańsk, Poland

tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail: viamedica@viamedica.pl